Home > Products > Optic Fiber Cable > Outdoor Optic Cable >

GYTA Non-Armored Loose Tube Single Jacket Cable

GYTA Non-Armored Loose Tube Single Jacket Cable

GYTA Non-Armored Loose Tube Single Jacket Cable
GYTA Non-Armored Loose Tube Single Jacket CableGYTA Non-Armored Loose Tube Single Jacket CableGYTA Non-Armored Loose Tube Single Jacket CableGYTA Non-Armored Loose Tube Single Jacket CableGYTA Non-Armored Loose Tube Single Jacket Cable
CategoriesOutdoor Optic Cable
AlbumView larger image
BrandGenesis Fiber optic cable manufacture
ModelGYTA
Brand NameGenesis
Model NumberGYTA
TypeFiber Optic Cable
CoresAs Per Buyers' Request
JacketPE Jacket
Central strengthFRP
Operating Tempreture-40°C ~ +70°C
Dynamic20 times O.D.
Permisson Bent Radius Static10 times
Installation MethodAerial and Duct
FOB portShenzhen
Terms of PaymentL/C, Western Union, MoneyGram, T/T, Paypal
Update Time2017-12-17
Detail Information
                              


Description

The fibers, either of single-mode or multimode type, are positioned in a loose tube made of high modulus plastic. The tubes are filled with a water-resistant filling compound. A steel wire sometimes sheathed with polyethylene(PE) for cable with high fibre count, locates in the center of core as a metallic strength member. Tubes (and fillers) are stranded around the strength member into a compact and circular cable core. An Aluminum Polyethylene Laminate (APL) is applied around the cable core, which is filled with the filling compound to protect it from water-ingress. Then, the cable is completed with a PE sheath.

Characteristics:

☆.Accurate fiber excess length ensures good mechanical and temperature performance.
☆.High strength loose tube that is hydrolysis resistant and special tube filling compound ensure a critical protection of fibre. 
☆.Specially designed compact structure is good at preventiing loose tubes from shrinking.

☆. The following measures are taken to ensure the cable watertight:

1)Steel wire used as the central strength member

2) Loose tube filling compound

3) 100% cable core filling

 .Fiber count: 12-144 cores.

Fiber Allocation Scheme

Fiber number Tube number Fiber per tube Fiber type
414 F/TubeSM G652D MM 50/125   MM 62.5/125
616F/Tube
818F/Tube
10110F/Tube
12-601-512F/Tube

Cable Construction Details

         Items Description
Number of fiber4-60cores
Filling rope 4-0
Moisture BarrierWater blocking system
Central strength memberMaterial FRP
size1.4mm
Inner sheathNo
Loose tubematerialPBT
diameterФ2.2(outer/inner)
Tube-fillingmaterialTube filling compound
Armoring Material  Aluminum
Outer sheathmaterialPE
diameter1.70±0.2mm

Cable Mechanical Characteristic

ItemsCable  diameterWeight
4cores to 60cores10.5±0.5mm85±10kg/km
Installation Temperature range  -15--+60
Operation and transport temperature -40-+70
Min Bending Radius(mm)Long term10D
short term20D
Min allowable Tensile Strength(N)Long term500
short term1200

Fiber Characteristic 

Fiber styleUnitSM G652DMM 50/125MM 62.5/125
conditionnm1310/1550850/1300850/1300
attenuationdB/km≤0.36/0.23≤3.0/1.0≤3.0/1.0
Dispersion1310nmPs/(nm*km)≥-3.4 ≤3.4..........
1550nmPs/(nm*km)≤18..........
1625nmPs/(nm*km)≤22  
Bandwidth850nmMHZ. KM.....≧400≧160
1300nmMHZ. KM.....≧800≧500
Zero dispersion wavelengthnm≧1302,≤1322..........
Zero dispersion slopePs(nm2*km)≤0.091..........
PMD Maximum Individual FiberPs√km≤0.2..........
PMD Design Link ValuePs√km≤0.08..........
Fibre cutoff wavelength λcnm≧1180,≤1330..........
Cable cutoff wavelength λccnm≤1260..........
MFD1310nmum9.2±0.4..........
1550nmum10.4±0.8..........
Numerical Aperture(NA) ......0.200±0.0150.275±0.015
Step(mean of bidirectional measurement)dB≤0.05≤0.10≤0.10
Irregularities over fiber length and point discontinuitydB≤0.05≤0.10≤0.10
Difference backscatter coefficientdB/km≤0.03≤0.08≤0.10
Attenuation uniformitydB/km≤0.01..............
Core diameterum......50±1.062.5±2.5
Cladding diameterum125.0±0.1125.0±0.1125.0±0.1
Cladding non-circularity%≤1.0≤1.0≤1.0
Coating diameterum242±7242±7242±7
Coating/chaffinch concentrically errorum≤12.0≤12.0≤12.0
Coating non circularity%≤6.0≤6.0≤6.0
Core/cladding conentricity errorum≤0.6≤1.5≤1.5
Curl(radius)um≤4..........

Packing Informations:

Packing material: Wooden drum 

Packing length: standard length of cable shall be 2000m. Other cable length is also available if required by customer

Drum size: 100*100*55cm

Packing weight:  190kg/drum

 